Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Previously submitted to: JMIR Medical Informatics (no longer under consideration since Nov 16, 2026)

Date Submitted: Nov 15, 2026
Open Peer Review Period: Nov 16, 2026 - Nov 16, 2026
(closed for review but you can still tweet)

NOTE: This is an unreviewed Preprint

Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).

Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.

Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.

Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.

Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

A Standards Framework and Quality Index for Patient-Generated Health Data in Clinical Trials and Real-World Evidence: Framework Development and Application to a Consumer Wearable Dataset

  • Yogesh Kumar Gupta

ABSTRACT

Background:

Patient-generated health data (PGHD), from electronic patient-reported outcomes (PROs) and wearables to ambient artificial intelligence (AI) transcripts, are increasingly used in decentralized trials and real-world evidence. The dominant clinical data standards (Clinical Data Interchange Standards Consortium [CDISC] Study Data Tabulation Model/Analysis Data Model, Observational Medical Outcomes Partnership Common Data Model [OMOP-CDM], and Fast Healthcare Interoperability Resources [FHIR] R4) were designed around clinician-generated data and provide no shared, required way to record who generated a data point, with which device and algorithm version, in which setting, and at what quality.

Objective:

To develop an end-to-end standards framework for PGHD spanning classification, provenance, quality grading, and interoperability mapping to CDISC, OMOP-CDM, and FHIR R4, and to demonstrate its quality index on a public consumer wearable dataset.

Methods:

The framework was developed in 3 phases: (1) domain mapping of PGHD types from decentralized trial literature and regulatory guidance; (2) a standards gap analysis of CDISC, OMOP-CDM, and FHIR R4 against 5 metadata requirements; and (3) design of the PGHD Quality Index (PGHD-QI), a 6-dimension instrument with an ordered, exhaustive rule assigning 3 tiers (Class A regulatory-grade, B research-grade, C exploratory). Five composite scenarios illustrated the operational consequences of missing provenance. PGHD-QI was applied with prespecified operational anchors to an open Apple Watch dataset with electroencephalography-based sleep stage labels: documentation and label metadata were scored for all 253 nights from 47 adults, and raw signals were scored in full for 1 night. Files from a second open dataset (Empatica E4, Dexcom G6) were audited against the same checklist. A counterfactual analysis re-tiered the worked night assuming better provenance.

Results:

Eight PGHD classes (P1-P8) were defined. All 3 standards lacked required fields for patient-as-generator provenance, device and algorithm version, home-setting context, and narrative fidelity; extensions were specified for each. Only 2 of 6 provenance items were documented, so all 253 nights were Class C regardless of signal quality. In the worked night, heart rate covered 859 of 860 30-second epochs (99.9%) with no gap longer than 31 seconds (Completeness and Consistency High), yet 276 samples (5.1%) in the same file lay outside the recorded session. Automated and expert sleep labels agreed on 80.8% of 218,277 epochs. The second dataset also documented 2 of 6 provenance items, and its continuous heart rate did not mark values unsupported by detected beats. Documenting provenance to Moderate would raise the worked night to Class B; with High provenance and device reliability it would meet Class A.

Conclusions:

For dense consumer wearable data, missing provenance metadata rather than signal quality was the binding constraint on evidentiary grade. The framework identifies fields sponsors can capture now and extensions for standards bodies to review. PGHD-QI thresholds require consensus refinement and multisite validation. Clinical Trial: Not applicable. This study did not involve a clinical trial or prospective enrollment of participants; it used publicly available, deidentified datasets.


 Citation

Please cite as:

Gupta YK

A Standards Framework and Quality Index for Patient-Generated Health Data in Clinical Trials and Real-World Evidence: Framework Development and Application to a Consumer Wearable Dataset

JMIR Preprints. 15/11/2026:117020

DOI: 10.2196/preprints.117020

URL: https://preprints.jmir.org/preprint/117020

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.