Development and Multicenter Validation of SNOMED CT–Mapped Implementation Value Set for Specimen Type in Clinical Laboratories

  • Shinae Yu; 
  • Kuenyoul Park; 
  • Eun-Jung Cho; 
  • Hyejin Ryu; 
  • Sumi Sung; 
  • John Hoon Rim; 
  • Ha Nui Kim; 
  • Min-Sun Kim; 
  • YeJin Oh; 
  • Ahjung Byun; 
  • AeKyung Kwon; 
  • Sollip Kim

ABSTRACT

Background:

Variability in local specimen type naming remains a barrier to semantic interoperability in laboratory data exchange. Standardized representation of specimen type as a distinct data element is needed to support interoperable laboratory information.

Objective:

This study aimed to develop and validate a clinically curated, SNOMED CT–mapped specimen type value set for implementation in the Korea Core Data for Interoperability (KR CDI).

Methods:

Local specimen type names were collected from six Korean institutions in May 2025. After exclusion of non-specimen, duplicate, and institution-specific terms, representative specimen terms were established by expert consensus and mapped to the SNOMED CT International Edition (2025-10-01). Coverage was assessed against a previously developed Logical Observation Identifiers Names and Codes (LOINC) reference set. External validation was performed at two independent university hospitals by assessing the applicability of the value-set terms and mapping local specimen terms to the value set.

Results:

Among 1,065 collected specimen type names, 659 curated local terms were consolidated into 174 representative terms across 24 categories. Of these, 136 (78.2%) were exactly mapped to a single SNOMED CT concept, 22 (12.6%) were represented using post-coordinated expressions, 14 (8.0%) were broadly mapped, and 2 (1.1%) were narrowly mapped. Thus, 158 of 174 terms (90.8%) were represented by either a single equivalent concept or post-coordination. External validation identified 73 (42.0%) and 130 (74.7%) of the 174 value-set terms as applicable at the two institutions, respectively. Of the local specimen terms evaluated, 75 of 647 (11.6%) and 279 of 295 (94.6%), respectively, were successfully mapped to the value set.

Conclusions:

We developed a clinically curated, SNOMED CT–mapped specimen type value set for KR CDI. Most representative specimen terms could be represented by existing SNOMED CT concepts or post-coordinated expressions, while external validation showed substantial variation in local terminology and mapping coverage between institutions. The value set may support standardized representation of specimen type information for interoperable laboratory data exchange. Broader validation and mapping guidance for complex local specimen terms are needed to support implementation across diverse healthcare settings. Clinical Trial: SNOMED CT; specimen type; semantic interoperability; terminology standardization; laboratory medicine


 Citation

Please cite as:

Yu S, Park K, Cho EJ, Ryu H, Sung S, Rim JH, Kim HN, Kim MS, Oh Y, Byun A, Kwon A, Kim S

Development and Multicenter Validation of SNOMED CT–Mapped Implementation Value Set for Specimen Type in Clinical Laboratories

JMIR Preprints. 21/09/2026:112551

DOI: 10.2196/preprints.112551

URL: https://preprints.jmir.org/preprint/112551

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.