Currently accepted at: JMIR Medical Informatics
Date Submitted: Jul 14, 2026
Date Accepted: Nov 5, 2026
This paper has been accepted and is currently in production.
It will appear shortly on 10.2196/106992
The final accepted version (not copyedited yet) is in this tab.
Tail-Aware Pre-Release Evaluation Protocol for Synthetic Clinical Data: Methodological Study Across Two Cohorts
ABSTRACT
Background:
Clinical data are hard to share, and synthetic clinical data are increasingly used to circulate and reuse information across systems without exposing real records. For such reuse to be safe, downstream utility must be verified before release. Quality is still judged mainly by aggregate distributional similarity, which averages over the distribution tails, where the highest-risk 3–5% of cardiovascular patients and the high-kurtosis biomarkers that flag them lie.
Objective:
We developed and evaluated a reusable tail-aware pre-release evaluation protocol to quantify whether differences in tail-region reconstruction fidelity propagate into downstream classifier utility.
Methods:
Four established scalers (Standard, Robust, Power, Quantile) and a hybrid head-tail scaler were paired with a tabular denoising diffusion probabilistic model (TabDDPM) and a conditional variational autoencoder (CVAE) on the KoGES-ARIRANG cohort (n = 4,928; seven shared high-kurtosis biomarkers). NHANES 2017–2018 provided external validation on the shared variables (n = 1,663). A NHANES-internal analysis widened coverage to 18 high-kurtosis variables by adding 11 NHANES-specific biomarkers. Downstream utility was evaluated using train-on-synthetic, test-on-real analysis across AUROC, AUPRC, recall, and expected calibration error.
Results:
With TabDDPM, scaler choice governed tail-reproduction accuracy from 8.2% to 135.1% of the original, while test-on-real AUROC differed by at most 2.98 points and every scaler pair remained equivalent within a ±0.05 AUROC margin. The pattern held in external validation and across all four metrics. The separation narrowed for the autoencoder, where higher-fidelity scalers improved stroke prediction. The one exception was mode collapse, where near-zero fidelity met chance-level AUROC (0.506–0.511), a boundary that shifted between cohorts. Overall-cohort summaries obscured cross-scaler calibration differences that became more apparent in the tail-enriched high-risk subgroup.
Conclusions:
Reconstruction fidelity alone does not predict downstream utility in synthetic clinical data with heavy-tailed biomarkers. Before such data are shared or reused, tail-region utility should be verified alongside aggregate fidelity using multiple evaluation metrics. Clinical Trial: Not applicable.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.